EWAI AA-7090

The AA-7090 is EWAI’s fifth-generation atomic absorption spectrometer, featuring an advanced graphite furnace built for high-precision analysis of complex samples.

  • Transverse Heating: Ensures uniform graphite furnace heating and reliability.
  • Longitudinal Zeeman Correction: Ideal for high-precision analysis under complex interferences.
  • Variable Magnetic Field: Optimizes field strength per element for accurate results.
  • Description
Description
  • AA-7090 is the fifth-generation atomic absorption spectrometer developed by EWAI. It combines the quality and precision that EWAI is known for with important new features.
  • The AA-7090 graphite furnace features a unique design with transverse heating, longitudinal Zeeman background correction and variable magnetic field intensity.
  • The Zeeman background correction is suitable for high precision analysis of samples with complex interference matrices.
  • Variable magnetic field intensity allows the operator to optimize field strength for each element, maximizing the Zeeman effect for accurate results every time.

SPECIFICATION

Optics

  • Wavelength Range: 190 nm to 900 nm
  • Bandwidth: 0.1, 0.2, 0.4, 1.0, and 2.0 nm (automatic switch)
  • Monochromator: Czerny-Turner Grating
  • Wavelength Accuracy / Indication Error: ± 0.1 nm
  • Wavelength Repeatability: ≤ 0.05 nm
  • Grating: 1800 lines / mm
  • Blaze Wavelength: 250 nm
  • Baseline Stability: Static baseline stability ≤ 0.002 A / 30 min, dynamic baseline stability ≤ 0.003 A / 30 min
  • Resolution: Better than 0.1 nm

Flame System Characteristics

  • Concentration of Cu: ≤ 0.02 μg / mL / 1%
  • Detection Limit: ≤ 0.003 μg / ml
  • RSD: ≤ 0.45%
  • Burner Head: Switchable 50 mm and 100 mm titanium burner head, titanium nebulizer, and high-performance glass nebulizer
  • Position Control: Optimization of height and angle, flame and hydride switch within one minute

Graphite Furnace System Characteristics

  • Concentration of Cd: ≤ 0.5×10-12 g
  • Detection Limit: ≤ 1×10-12 g
  • RSD: ≤ 3.0%
  • Temperature Control: Max 20-step temperature program with 3 temperature rise modes (step, slope, and flat)
  • Heating Mode: Power heating
  • Heating Rate: ≥ 2500℃ / s

Background Correction

  • Background correction is available for both flame and graphite furnace methods. Deuterium lamp for flame. deuterium lamp or Zeeman for graphite furnace.
  • Correction Mode: Deuterium lamp, Zeeman Correction Capability:
    • Deuterium Lamp: When background absorption approaches 1.0 Abs, the instrument is capable of a background correction of 60 times or more.
    • Zeeman: When background absorption approaches 2.0 Abs, the instrument is capable of a background correction of 100 times or more.

ANY QUERY, CLICK HERE !

SPECTRON

At  Spectron Instruments Pvt. Ltd., we believe in building long-term relationships with our clients and take pride in working “with”  them rather than merely “for”  them, ensuring reliable results and lasting partnerships.

Quick links

HOME
ABOUT US
PRODUCTS
APPLICATION
SUPPORT
CONTACT US

Contact us

Head Office :

4A/1, Om Sudama Soc., Old Mumbai Poona Rd., Sudama Nagar, Thane - 400 605.

Email us:

spectroninstruments@gmail.com

Call on :

+91 9987117010

Close
  • Home
  • About us
  • Product
  • Application
  • Support
  • Contact us