XGM-500+
This Instrument is used forforensic analysis, mineral analysis, geological sample testing, and quality control sample analysis and R&D.
- Minerals, Mining, Geology
- Cement & Construction Materials
- Petro chemistry & Polymers
- Ferrous and Non-Ferrous Metals
- Research & Development, Academia
- Analyze everything fast, the direct-excitation beam path makes full use of the 50 watt power tube
- 100KV high voltage unit for wide elemental coverage
- Multiple automated tube filters for enhanced sensitivity
- Multi-instrument hardware protection system, and real-time monitoring of the whole process through software, making the instrument work more stable and safer
- Dedicated light element configuration for best analytical performance of various elements
- HD camera for sample verification
| Element Range: | Na – U (Optional F – Am) |
| Core dimension: | 650mm*610mm*1040mm |
| Detector: | Next Generation Peltier cooled FSDD High-throughput count rate wide linear dynamic range: 1000- 1000000cps, including signal enhancement processing module SNE |
| Digital Pulse Analyzer: | 4096 channels, Peak drift is less than 0.5 channel (24 hours) |
| X-ray tube: | 100kV/50 W High-power long-life-time X-ray tube with beryllium window |
| High-voltage Unit: | High precision HV unit with its own voltage overload protection |
| Sample observation system: | High-definition CCD camera, including sample spot image positioning function |
| Collimator Filter: | Automatic 8-sizes changer 8-position automatic filter changer |
| Concentration range: | ppm to 100% |
| Sample Chamber: | Air, Vacuum, filled with Helium (optional). Built-in-high-power vacuum pump, automatic software control and adjustment of vacuum system, dual vacuum pumping speed mechanism, standard vacuum degree automatic stabilization system |
| Power requirement: | 220ACV 50/60HZ |
MA-OES 1000
MA-OES 1000 is a microwave plasma-based optical emissions spectroscopy instrument that runs on 98% nitrogen, significantly improving infrastructural and safety challenges posed by other products.
- High-resolution CCD provides measurement of elements in the prepared sample.
- Portability and small footprint – Weighing 34kg (19kg plasma source and 15kg spectrometer module), [33×45 com] allows sufficient space for auto sampler and associated chemistry needs.
- Better safety and logistics – No chiller or argon infrastructure needed.
- Operating cost saving – Minimizes annual operating costs based on nitrogen consumption and infrastructure.
- Broad sample tolerance – Plasma can handle a broad array of samples including high amounts of total dissolved solids and organics.
- Electrical outlet compatibility – 110V 220V drawing less than 2kW of power. Can also run on a portable generator.
BSD660
The BSD660 is a high-performance surface area and porosity analysis system designed for advanced material characterization in research, quality control, and industrial applications.
- High-throughput and Fast Specific Surface Area Analysis;
- Pore Volume and Meso-, Micro-, Ultra Micro-pore Size Distribution Analysis;
- Gas Adsorption Isotherm (E.g. N2, O2, Ar, CO, CO2);
- Combustible Gas Adsorption Isotherm (E.g. H2, CH4, C2H6).
- Test Range: > 0.0005m2/g for specific surface area; 0.35nm – 500nm for pore size;
- High Accuracy: < 0.5% RSD (BET value of standard Sample as reference);
- Pressure Transducer: Transducers are equipped for each analytic station, P0 station and calibrated volume respectively, which work independently with precision at 0.15%;
- Vaccum System: 10-2 Pa with mechanical pump; 10-8 Pa with molecular pump.
BSD-MGC 18
The system is designed for fully automated gas adsorption analysis, enabling seamless selection and switching between multiple gases for accurate and repeatable measurements.
- Channel 1 : N₂ – BET surface area, adsorption-desorption isotherms
- Channel 2: He – Free space / leak check / calibration
- Channel 3: Ar – Micropore analysis (better than N₂ for some materials)
- Channel 4: CO₂ – Ultramicropore analysis at 273 K
- Optional gases may include: H₂, CH₄, Kr, etc. depending on instrument model & configuration.
- Automatic selection & switching between multiple gases.
- Accurate gas dosing into sample/manifold using calibrated dosing volumes.
- Integrated pressure monitoring & control for stable adsorption measurements.
- Automated sequences for: – He free space / void volume measurement.
- N₂ adsorption-desorption (BET / BJH)
- Ar adsorption for microporous materials
- CO₂ adsorption (273K) for ultramicropore analysis
- Line purging / evacuation / venting
BSD VD 12
The system is a high-efficiency sample degassing unit designed for accurate surface area and porosity analysis. With two independent stations and 12 sample positions, it enables simultaneous degassing with flexible temperature control.
- Dual Independent Stations -2 stations, 12 total positions for simultaneous degassing.
- Flexible Temperature Settings -Adjustable temps for different sample types.
- Precise Control –Standard 400°C, ±0.1°C accuracy.
- Automatic Pumping Speed -Pressure-controlled, prevents sample loss, ensures high vacuum.
- Touch-Screen Controller -32-segment programmable, visual temperature control.
- Cooling Options -Air-cooled & water-cooled degassing positions.
- Completion Monitoring -Pressure-based detection of degassing completion.
- Cold Trap -Protects samples (MOF, COF) & vacuum system from contamination.
- Degas Curve Log -Screen check, record and search of degas curve log
- Stations- 2 with independent temperature setting
- Sample capacity – 12 ports, 6 ports per station
- Backfill gas – Helium, nitrogen, argon, or any other pure gas that does not adsorb at room temperature
- Heating – -400℃ ±0.1℃ , visual 32 step programmed heating
- Cooling -12 air cooling positions
- Vacuum system- Mechanical Pump Vaccum Leve 1Pa
- Cold trap – Optional
- Suitable- Analyzers BSD-660 Series; BSD-PH Series